Part Number Hot Search : 
N4005 N4005 332ML PT100 MB400 74AC1 RFP448 MAX131
Product Description
Full Text Search
 

To Download RPT-6011 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification model rpt-60a dc voltage rated current current range rated power output setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage 5v 4a 0.5 ~ 4.4a 46.5w 51.15w 80mvp-p +3,-2% 0.5% 1.5% 200ms, 15ms/230vac 200ms, 15ms/115vac at full load 70ms/230vac 15ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz ch1: 5.75 ~ 6.75v 77% 1.1a/115vac 0.7a/230vac cold start 60a/230vac 30a/115vac 115 ~ 150% rated output power -20 ~ +65 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 60w triple output medical type r p t- 6 0 s e r i e s withstand voltage isolation resistance environment safety & emc (note 5) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. 33% duty cycle maximum within every 30 seconds. average output power sho uld not exceed the rated power. 5. the power supply is considered a component which will be installed into a f inal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 6. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 7. heat sink hs1,hs2 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) ripple & noise (max.) note.2 voltage tolerance note.3 features : protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : shut down o/p voltage, re-power on to recover rpt-60b rpt-60c 12v ch2 ch2 ch2 -5v ch3 ch3 ch3 12v -12v 15v -15v 5v 5v 2a 0.5a 0.1 ~ 0.55a 2a 0.5a 0.1 ~ 0.55a 1.5a 0.1 ~ 1.65a 0.5a 0.1 ~ 0.55a 4a 0.5 ~ 4.4a 4a 0.1 ~ 2.2a 0.1 ~ 2.2a 0.5 ~ 4.4a 50w 55w 50w 55w 80mvp-p 80mvp-p 80mvp-p 100mvp-p 100mvp-p 150mvp-p 80mvp-p 80mvp-p 6.0% +9,-8% 6.0% +10,-6% 6.0% 8.0% 1.0% 2.0% 1.0% +5,-7% 2.0% 1.0% 5.0% 2.0% 3.0% 2.0% 4.0% 2.0% +3,-2% +3,-2% 0.5% 1.5% 0.5% 1.5% 78% 79% line regulation load regulation ch1 ch1 ch1 output number peak load(10sec.) note.4 677.8khrs min. mil-hdbk-217f (25 ) 101.6*50.8*29mm (l*w*h) file name:rpt-60-spec 2011-03-31 ul60950-1, tuv en60950-1, ul60601-1, tuv en60601-1, iec60601- 1 approved compliance to en55011(cispr11),en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, e n60601-1-2, en61204-3, medical level, criteria a i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh 4"x2" miniature size universal ac input / full range low leakage current<200ua protections: short circuit / overload / over voltage cooling by free air convection ul60601-1/iec60601-1/en60601-1 medical safety approved fixed switch frequency at 100khz 3 years warranty ul60950-1/iec60950-1/en60950-1 ite safety approved 0.15kg; 96pcs/15.4kg/0.89cuft for earth <200ua/264vac, for patient <100ua/264vac en60601-1iec60601-1
specification model rpt-60d dc voltage rated current current range rated power output setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards harmonic current ems immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage 5v 3.5a 0.5 ~ 3.85a 47.5w 52.25w 80mvp-p +3,-2% 0.5% 1.5% 200ms, 15ms/230vac 200ms, 15ms/115vac at full load 70ms/230vac 15ms/115vac at full load 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz ch1: 5.75 ~ 6.75v 79% 1.1a/115vac 0.7a/230vac cold start 60a/230vac 30a/115vac 115 ~ 150% rated output power -20 ~ +65 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 45 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 60w triple output medical type r p t- 6 0 s e r i e s withstand voltage isolation resistance environment safety & emc (note 5) protection emi conduction & radiation 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. 33% duty cycle maximum within every 30 seconds. average output power sho uld not exceed the rated power. 5. the power supply is considered a component which will be installed into a f inal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 6. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 7. heat sink hs1,hs2 can not be shorted. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) ripple & noise (max.) note.2 voltage tolerance note.3 features : protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : shut down o/p voltage, re-power on to recover rpt-6003 24v ch2 ch2 12v ch3 ch3 5v 12v 3.3v 1a 0.5a 0.1 ~ 0.55a 3a 0.7a 0.1 ~ 0.77a 5a 0.5 ~ 5.5a 0.1 ~ 1.1a 0.3 ~ 3.3a 39.9w 43.9w 150mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 6.0% 8.0% 8.0% +10,-6% 2.0% 3.0% 2.0% 4.0% 2.0% 1.0% +5.5,-5% 2.0% +3,-2% 0.5% 1.5% 75% ch1: 3.8 ~ 4.45v line regulation load regulation ch1 ch1 output number peak load(10sec.) note.4 677.8khrs min. mil-hdbk-217f (25 ) 101.6*50.8*29mm (l*w*h) file name:rpt-60-spec 2011-03-31 compliance to en55011(cispr11),en55022 (cispr22) class b compliance to en61000-3-2,-3 i/p-o/p:4kvac i/p-fg:1.5kvac o/p-fg:1.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh 4"x2" miniature size universal ac input / full range low leakage current<200ua protections: short circuit / overload / over voltage cooling by free air convection ul60601-1/iec60601-1/en60601-1 medical safety approved fixed switch frequency at 100khz 3 years warranty ul60950-1/iec60950-1/en60950-1 ite safety approved compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024, e n60601-1-2, en61204-3, medical level, criteria a 0.15kg; 96pcs/15.4kg/0.89cuft for earth <200ua/264vac, for patient <100ua/264vac en60601-1iec60601-1 ul60950-1, tuv en60950-1, ul60601-1, tuv en60601-1, iec60601- 1 approved
mechanical specification unit:mm block diagram circuit detection o.l.p. emi filter rectifiers & filter filter filter filter & & & rectifiers rectifiers rectifiers +v1 +v2 v3 com i/p fg control o.v.p. output derating vs input voltage input voltage (vac) 60hz 90 100 95 120 115 160 140 200 180 240 220 264 load (%) ta=25 90 100 80 70 60 50 40 fosc : 100khz ac input connector (cn1) : jst b3p-vh or equivalent pin no. 12 3 assignment ac/n no pin ac/l mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal dc output connector (cn2) : jst b6p-vh or equivalent pin no. 1,2 3,4 56 assignment v1 v2 v3 mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent 3 14 25 6 cn2 4- 3.3 101.6 50.8 95.25 cn1 fs1 fs2 2 3 1 (horizontal) 65 com 44.45 derating curve 3.175 3.175 power switching ac fuse t2.5/250v ac fuse t2.5/250v 29 3 max. hs1 hs2 hs1,hs2 can not be shorted ambient temperature ( ) load (%) -20 0 20 10 30 40 20 40 80 60 100 60 50 70 file name:rpt-60-spec 2011-03-31 60w triple output medical type r p t- 6 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of RPT-6011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X